Applications
▪ Distributed wind turbine power grid-tied system
▪ Solar&wind hybrid power grid-tied system
▪ Wind power grid-tied system
Features
▪ Wind Controller&Inverter integrated machine
▪ MPPT included, and 30-point power curve can be settable
▪ Complete protection functions
▪ RS485/GPRS monitoring modes optional
WWGI Series 3KW Wind Power controller and Grid-tied Inverter
WWGI Series is wind power grid-tied controller&inverter integrated machine with MPPT function. It looks concise and can be easily operated.
System Diagram
Technical Parameters
WWGI30 |
|
3kW |
|
Max. input power |
4.5kW
|
Rated input voltage |
240Vac |
Rated input current |
7.2A
|
Max input current |
10.8A |
Cutting speed |
60RPM(factory default,0-1499RPM settable) |
Power tracking |
30 points set power curve |
Speed limit control |
Electromagnetic speed limit |
Manual brake |
Press “Enter” and “ESC” at the same time to completely unload |
Tune the switch on the panel to "Brake", three-phase AC short circuit, turn to "RUN" to run. |
|
Brake by overcurrent |
12A(factory default,0-15A settable)it dumps load completely when over current, and will recover after 10mins automatically |
300r/min(factory default,0~1499r/min settable)Unload completely when reached the set rotational speed, and recover automatically after 10mins.
|
|
18m/s (0~30m/s settable), it dumps load completely when reached the set wind speed, and recover automatically after working 10mins and wind speed is less than 15m/s. |
|
AC Output |
|
Grid Type |
Three-phase |
Rated output power |
3kW |
Max output power |
3.3kW |
Rated Grid voltage |
220Vac |
Grid voltage range |
85%~110% of rated grid voltage |
Rated Grid frequency |
50Hz/60Hz |
Work frequency range |
49Hz~51Hz/59Hz~61Hz |
Rated output current |
13.6A |
Rated power factor |
>0.98 |
Thdi |
<5% |
DC component |
<0.5% |
soft start |
Yes |
Restoring grid-connected functionality |
Yes |
Auto on/off |
Yes |
Grid overvoltage/undervoltage protection |
Yes |
Grid over frequency/under frequency protection |
Yes |
output short circuit protection |
Yes |
Grid power failure protection |
Yes |
Anti-islanding protection |
Yes |
Over-temperature protection |
Yes |
Lightning protection |
Yes |
Residual current protection |
Yes |
General Parameters |
|
Display mode |
LED+LCD |
Display information |
Display: wind Voltage, Wind current,Wind power, Wind Speed, Pole Paris; Inverter voltage, Inverter current, Inverter Power, Inverter Frequency, Relay Time, power generation; BUS Voltage, Air speed, Temperature, Time, Language, ID, etc. Status: Manual brake, automatic brake, fault indication, grid-connected state, relay state, Wind cut-in, etc. |
Monitoring mode(optional) |
RS485/GPRS
|
Monitoring contents |
Telemetry: wind turbine speed, Inverter voltage, Inverter current, Inverter power, power generation,Air speed; Remote signal: wind turbine status, wind power grid-connected inverter over-current alarm, over-voltage alarm, over-temperature alarm, fault alarm, etc.; Remote control: modify the parameters of the wind power |
Efficiency |
≥95% |
Ambient temperature |
-20℃~+40℃ |
Humidity |
0%~90%, no condensing |
Vibration resistance |
Can withstand sine wave vibration with a frequency of 10Hz~55Hz and an amplitude of 0.35mm |
Noise |
≤65dB |
Cooling mode |
Natural cooling |
Cover protection class |
IP65(dump load IP54) |
Product reference dimension |
416×536×250mm |
Product reference weight |
20kg |
Dump load reference dimension |
300×550×55mm |
Dump load reference weight |
14kg |