Technical Parameters
2KW
Model |
WWS20-120 |
WWS20-48 |
Wind Turbine Input |
||
Rated input power |
2kW |
|
Rated input voltage |
120Vdc |
48Vdc |
Input voltage range |
0~160Vdc |
0~64Vdc |
Rated input current |
17A |
42A |
Brake by hand |
Keep press the button for 5s to unload completely, and then recover by hand. |
|
Switch “ON” the brake switch |
||
Brake by over current |
17A (factory default, 0~17A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
42A (factory default, 0~42A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
Brake by overvoltage |
Refer to “output overvoltage” control |
|
Brake by over wind speed (optional) |
18m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after working 10mins. |
|
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
|
PV Input |
||
Rated input power |
600W |
|
Max. Open circuit voltage |
240Vdc |
96Vdc |
Rated input current |
5A |
13A |
Reversed connection protection |
YES |
YES |
Charge Parameters |
||
Rated battery voltage |
120Vdc |
48Vdc |
Temperature compensation function (optional) |
-3mV/℃/2V |
|
Output Parameters |
||
Rated output voltage |
120Vdc |
48Vdc |
Output overvoltage point |
145Vdc |
58Vdc |
output overvoltage recovery point |
it will recover automatically once it is lower than output overvoltage point. |
|
Max. Output current |
17A |
42A |
General Parameters |
||
Rectifier mode |
Uncontrolled rectifier |
|
Display mode |
LCD |
|
Display information |
DC output voltage, wind voltage/current/power, battery voltage, PV voltage/current/power. |
|
Monitoring mode (optional) |
RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee |
|
Monitoring Contents |
DC output voltage, wind voltage/current/power, battery voltage, PV voltage/current/power. |
|
parameter setting: output overvoltage point, wind overcurrent point and manual brake |
||
Lightning protection |
YES |
|
Conversion efficiency |
≥95% |
|
Static loss |
<2W |
<1W |
Ambient temperature |
-20℃~+40℃ |
|
Humidity |
0~90%, No condensing |
|
Noise |
≤65dB |
|
Cooling mode |
Natural cooling |
|
Installation mode |
Wall-mounted |
|
Cover protection class |
IP20 |
|
Product dimension (W*H*D) |
420×440×175 mm |
|
Product net weight |
11.5kG |
3KW |
|
|
|
||
Model |
WWS30-48 |
WWS30-120 |
|||
Wind Turbine Input |
|
|
|
||
Rated input power |
3kW |
||||
Rated input voltage |
48Vdc |
120Vdc |
|||
Input voltage range |
0~64Vdc |
0~160Vdc |
|||
Rated input current |
63Adc |
25Adc |
|||
Brake by hand |
Press button “Enter” “Esc” at the same time to unload completely. Then recover by hand. |
||||
Brake by over current |
63A (factory default, 0~63A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
25A (factory default, 0~25A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
|||
Brake by overvoltage |
Refer to “output overvoltage” control |
||||
Brake by over wind speed |
Optional |
||||
Brake by over rotational Speed |
Optional |
||||
PV Input (optional) |
|
|
|
||
Rated input power |
900W |
||||
Max. Open circuit voltage |
96Vdc |
240Vdc |
|||
Rated input current |
19Adc |
8Adc |
|||
Reversed connection protection |
YES |
||||
Charge Parameters (optional) |
|
||||
Rated battery voltage |
48Vdc |
120Vdc |
|||
Temperature compensation function (optional) |
-3mV/℃/2V |
||||
Output Parameters |
|
||||
Rated output voltage |
48Vdc |
120Vdc |
|||
Output overvoltage point |
58Vdc |
145Vdc |
|||
Output overvoltage recovery point |
Less than output overvoltage |
||||
Max. Output current |
63Adc |
25Adc |
|||
General Parameters |
|
||||
Rectifier mode |
Uncontrolled rectifier |
||||
Display mode |
LCD |
||||
Display information |
DC output voltage, wind turbine voltage/current/power/battery voltage and PV power/voltage/current |
||||
Monitoring mode (optional) |
RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee |
||||
Monitoring Contents |
Real-time display:DC output voltage,
wind turbine voltage/current/power/battery voltage and PV
power/voltage/current |
||||
Lightning protection |
YES |
||||
Conversion efficiency |
≥95% |
||||
Static loss |
<5W |
<7W |
|||
Ambient temperature |
-20℃~+40℃ |
||||
Humidity |
5%~95%, No condensing |
||||
Noise |
≤65dB |
||||
Cooling mode |
Natural cooling |
||||
Installation mode |
Wall-mounted |
||||
Cover protection class |
IP20 |
||||
Product dimension (W*H*D) |
440×305×170 mm |
||||
Product net weight |
7.5kG |
||||
Dump load dimension(W*H*D) |
400×390×210mm |
||||
Dump load weight |
13.5kG |
||||
Note: the listed specs are just for your reference |
|||||
5KW |
|
|
|||
Model |
WWS50-48 |
WWS50-120 |
WWS50-240 |
||
Wind Turbine Input |
|||||
Rated input power |
5kW |
||||
Rated input voltage |
48Vdc |
120Vdc |
240Vdc |
||
Input voltage range |
0~64Vdc |
0~160Vdc |
0~320Vdc |
||
Rated input current |
105Adc |
42Adc |
21Adc |
||
Brake by hand |
Press button “Enter” “Esc” at the same time to unload completely. Then recover by hand. |
||||
Brake by over current |
105A (factory default, 0~105A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
42A (factory default, 0~42A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
21A (factory default, 0~21A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
||
Brake by overvoltage |
Refer to “output overvoltage” control |
||||
Brake by over wind speed (optional) |
14m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after working 10mins. |
||||
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
||||
PV Input (optional) |
|||||
Rated input power |
1500W |
||||
Max. Open circuit voltage |
96Vdc |
240Vdc |
480Vdc |
||
Rated input current |
32Adc |
13Adc |
7Adc |
||
Reversed connection protection |
YES |
||||
Charge Parameters (optional) |
|||||
Rated battery voltage |
48Vdc |
120Vdc |
240Vdc |
||
Temperature compensation function (optional) |
-3mV/℃/2V |
||||
Output Parameters |
|||||
Rated output voltage |
48Vdc |
120Vdc |
240Vdc |
||
Output overvoltage point |
58Vdc |
145Vdc |
290Vdc |
||
Output overvoltage recovery point |
Less than output overvoltage |
||||
General Parameters |
|||||
Rectifier mode |
Uncontrolled rectifier |
||||
Display mode |
LCD |
||||
Display information |
DC output voltage, wind turbine voltage/current/power/battery voltage and PV power/voltage/current |
||||
Monitoring mode (optional) |
RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee |
||||
Monitoring Contents |
Real-time display:DC output
voltage, wind turbine voltage/current/power/battery voltage and PV
power/voltage/current |
||||
Lightning protection |
YES |
||||
Conversion efficiency |
≥95% |
||||
Static loss |
<5W |
<5W |
<5W |
||
Ambient temperature |
-20℃~+40℃ |
||||
Humidity |
5%~95%, No condensing |
||||
Noise |
≤65dB |
||||
Cooling mode |
Natural cooling |
||||
Installation mode |
Wall-mounted |
||||
Cover protection class |
IP42 |
||||
Product dimension (W*H*D) |
440×425×170 mm |
440×305×170 mm |
|||
Product net weight |
12kG |
7.5kG |
|||
Dump load dimension(W*H*D) |
730×390×190mm |
||||
Dump load weight |
19kG |
||||
Note: the listed specs are just for your reference |
|||||
|
10KW
Model |
WWS100-240 |
WWS100-120 |
|
Wind Turbine Input |
|||
Rated input power |
10kW |
10kW |
|
Rated input voltage |
240Vdc |
120Vdc |
|
Input voltage range |
0~320Vdc |
0~160Vdc |
|
Rated input current |
42Adc |
84Adc |
|
Brake by hand |
Press button “Enter” “Esc” at the same time to unload completely. Then recover by hand. |
||
Brake by over current |
42A (factory default, 0~42A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
84A (factory default, 0~84A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
|
Brake by overvoltage |
Refer to “output overvoltage” control |
||
Brake by over wind speed (optional) |
14m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after working 10mins. |
||
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
||
PV Input (optional) |
|||
Rated input power |
3000W |
3000W |
|
Max. Open circuit voltage |
480Vdc |
240Vdc |
|
Rated input current |
13Adc |
25Adc |
|
Reversed connection protection |
YES |
||
Charge Parameters (optional) |
|||
Rated battery voltage |
240Vdc |
120Vdc |
|
Temperature compensation function (optional) |
-3mV/℃/2V |
||
Output Parameters |
|||
Rated output voltage |
240Vdc |
120Vdc |
|
Output overvoltage point |
58Vdc |
145Vdc |
|
Output overvoltage recovery point |
Less than output overvoltage |
||
General Parameters |
|||
Rectifier mode |
Uncontrolled rectifier |
||
Display mode |
LCD |
||
Display information |
DC output voltage, wind turbine voltage/current/power/battery voltage and PV power/voltage/current |
||
Monitoring mode (optional) |
RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee |
||
Monitoring Contents |
Real-time display:DC output
voltage, wind turbine voltage/current/power/battery voltage and PV
power/voltage/current |
||
Lightning protection |
YES |
||
Conversion efficiency |
≥95% |
||
Static loss |
<7W |
||
Ambient temperature |
-20℃~+40℃ |
||
Humidity |
5%~95%, No condensing |
||
Noise |
≤65dB |
||
Cooling mode |
Natural cooling |
||
Installation mode |
Wall-mounted |
||
Cover protection class |
IP42 |
||
Product dimension (W*H*D) |
440×305×170 mm |
||
Product net weight |
9kG |
||
Dump load dimension(W*H*D) |
520×550×430mm |
||
Dump load weight |
45kG |
||