Applications
• Independent wind power plant&Independent household wind power generation system
• Power supply for those unmanned regions like mobile communication station, high way, the coastal islands, remote mountainous regions and border posts.
• Regional research projects, government demonstration projects, landscape lighting projects for those places with insufficient power or power shortages.
Features
• Can be applied to grid-tied system, off-grid system and grid-tied energy storage system.
• RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee optional.
• MPPT power curve settable
• protection function Standard
• MODBUS protocol optional
Technical Parameters
1KW | ||
Model | WW10-48-48 | WW10-240-48 |
Type | Boost | |
Wind Turbine Input | ||
Rated input power | 1kW | |
Rated input voltage | 56Vdc | |
Input voltage range | 12~64Vdc | |
Start charge voltage | 12Vdc (factory default, settable) | |
Rated input current | 21Adc | |
Brake by hand | Keep press the button for 5s to unload completely, and then recover by hand. | |
Switch “ON” the brake switch | ||
Brake by over current |
25A (factory default, 0~25A settable ) unload completely when reached the set current, and recover automatically after working 10mins. |
|
Brake by overvoltage | Refer to “output overvoltage” control | Refer to “output overvoltage” control |
Brake by over wind speed (optional) |
18m/s (0~30m/s settable), unload completely when reached the set wind speed, and recover automatically after 10mins (and the speed should be less than 15m/s.) |
|
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1000r/min settable) Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
|
Charge Parameters (optional) | ||
Rated battery voltage | 48Vdc | 240Vdc |
Temperature compensation function (optional) |
-3mV/℃/2V | |
Output Parameters | ||
Rated output voltage | 48Vdc | 240Vdc |
Start unload voltage |
56Vdc (factory default, 44Vdc~64Vdc settable) |
280Vdc (factory default, 220Vdc~320Vdc settable) |
Complete unload voltage |
58Vdc (factory default, add 2V to the start unload voltage) |
300Vdc (factory default, add 10V to the start unload voltage) |
Max. Output current | 21Adc | 5Adc |
General Parameters | ||
Rectifier mode | Uncontrolled rectifier | |
Display mode | LCD | |
Display information |
DC output voltage, wind turbine voltage/current/power. For those with charge control function, Battery voltage is showed as well. |
|
Monitoring mode (optional) | RS232/RS485/RJ45/GPRS/ Bluetooth /Zigbee | |
Monitoring Contents |
Real-time display: DC output voltage, wind turbine voltage/current/power. For those with charge control function, Battery voltage is showed as well. |
|
Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, and wind turbine brake settings. |
||
Lightning protection | YES | |
Conversion efficiency | ≥92% | |
Static loss | <2W | <2W |
Ambient temperature | -20℃~+40℃ | |
Humidity | 5~95%, No condensing | |
Noise | ≤65dB | |
Cooling mode | Forced air cooling | |
Installation mode | Wall-mounted | |
Cover protection class | IP42 | |
Product dimension (W*H*D) |
300×375×145mm | |
Product net weight | 10kg | |
Dump load dimension (W*H*D) |
360*80*120mm | |
Dump load net weight | 2.8kg | |
Note: Part of parameters can be adjusted according to customer’s specific demand. |
2KW | ||
Model | WW20-48-48 | WW20-48-240 |
Type | Boost | Buck |
Wind Turbine Input | ||
Rated input power | 2kW | |
Rated input voltage | 56Vdc | 280Vdc |
Input voltage range | 12~64Vdc | 60~320Vdc |
Start charge voltage | 12Vdc (factory default,8Vdc~64Vdc settable) | 60Vdc (factory default,40Vdc~320Vdc settable) |
Rated input current | 42Adc | 9Adc |
Brake by hand | Keep press the button for 5s to unload completely, and then recover by hand. | |
Switch “ON” the brake switch | ||
Brake by over current |
50A (factory default,0~50A settable) Unload completely when reached the set current,and recover automatically after working 10mins. |
10Adc (factory default,0~10A settable) Unload completely when reached the set current, and recover automatically after working 10mins. |
Brake by overvoltage | Refer to “output overvoltage” control |
320Vdc (factory default,220Vdc~320Vdc settable )PWM unload step by step once reached the set unload voltage, and it will unload completely if the voltage rise 20Vdc more. |
Brake by over wind speed (optional) |
18m/s (0-30m/s settable),Unload completely when reached the set wind speed, and recover automatically after working 10mins. |
|
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
|
Charge Parameters (optional) | ||
Rated battery voltage | 48Vdc | |
Temperature compensation function (optional) |
-3mV/℃/2V | |
Output Parameters | ||
Rated output voltage | 48Vdc | |
Start unload voltage | 56Vdc (factory default,44Vdc~64Vdc settable) | |
Complete unload voltage | 58Vdc (factory default, add 2V to the start unload voltage) | |
Max. Output current | 42Adc | |
General Parameters | ||
Rectifier mode | Uncontrolled rectifier | |
Display mode | LCD | |
Display information |
DC output voltage, wind turbine voltage/current/power. For those with charge control function, Battery voltage is showed as well. |
|
Monitoring mode (optional) | RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee | |
Monitoring Contents |
Real-time display: DC output voltage, wind turbine voltage/current/power. For those with charge control function, Battery voltage is showed as well. |
|
Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, and wind turbine manual brake button. |
||
Lightning protection | YES | |
Conversion efficiency | ≥92% | |
Static loss | <5W | |
Ambient temperature | -20℃~+40℃ | |
Humidity | 0~90%,No condensing | |
Noise | ≤65dB | |
Cooling mode | Forced air cooling | |
Installation mode | Wall-mounted | |
Cover protection class | IP42 | |
Product dimension (W*H*D) | 300×375×145mm | |
Product net weight | 10kg | |
Dump load dimension (W*H*D) |
300*400*210 mm | |
Dump load net weight | 9kg | |
Note: Part of parameters can be adjusted according to customer’s specific demand. |
3KW | |||
Model | WW30-48-240 | WW30-120-120 | WW30-240-240 |
Type | Buck | Boost | |
Wind Turbine Input | |||
Rated input power | 3kW | ||
Rated input voltage | 280Vdc | 140dc | 280Vdc |
Input voltage range | 60~320Vdc | 30~160Vdc | 60~320Vdc |
Start charge voltage |
60Vdc (factory default ,40Vdc~320Vdc settable) |
30Vdc (factory default ,20Vdc~160Vdc settable) |
60Vdc (factory default, 40Vdc~320Vdc settable) |
Rated input current | 13Adc | 25Adc | 13Adc |
Brake by hand | Keep press the button for 5s to unload completely, and then recover by hand. | ||
Switch “ON” the brake switch | |||
Brake by over current |
15Adc (factory default,0~15A settable) Unload completely when reached the set current, and recover automatically after working 10mins. |
30A (factory default,0~30A settable) Unload completely when reached the set current, and recover automatically after working 10mins. |
15Adc (factory default,0~15A settable) Unload completely when reached the set current, and recover automatically after working 10mins. |
Brake by overvoltage |
320Vdc (Factory default), PWM unload step by step once reached the set unload voltage, and it will unload completely if the voltage rise 20Vdc more. |
Refer to “output overvoltage” | |
Brake by over wind speed (optional) |
18m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after 10mins (and the speed should be less than 15m/s.) |
||
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
||
Charge Parameters (optional) | |||
Rated battery voltage | 48Vdc | 120Vdc | 240Vdc |
Temperature compensation function (optional) |
-3mV/℃/2V | ||
Output Parameters | |||
Rated output voltage | 48Vdc | 120Vdc | 240Vdc |
Start unload voltage |
56Vdc (factory default ,44Vdc~64Vdc settable) |
140Vdc (factory default, 110Vdc~160Vdc settable) |
280Vdc (factory default, 220Vdc~320Vdc settable) |
Complete unload voltage |
58Vdc(factory default ,add 2V to the start unload voltage) |
145Vdc (factory default, add 5V to the start unload voltage) |
290Vdc (factory default, add 10V to the start unload voltage) |
Max. Output current | 42Adc | 25Adc | 13Adc |
General Parameters | |||
Rectifier mode | Uncontrolled rectifier | ||
Display mode | LCD | ||
Display information |
DC output voltage, wind turbine voltage/current/power. For those with charge control function, Battery voltage is showed as well. |
||
Monitoring mode (optional) | RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee | ||
Monitoring Contents |
Real-time display: DC output voltage, wind turbine voltage/current/power. For those with charge control function, Battery voltage is showed as well. |
||
Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, and wind turbine manual brake button. |
|||
Lightning protection | YES | ||
Conversion efficiency | ≥95% | ||
Static loss | <5W | ||
Ambient temperature | -20℃~+40℃ | ||
Humidity | 0~90%, No condensing | ||
Noise | ≤65dB | ||
Cooling mode | Forced air cooling | ||
Installation mode | Wall-mounted | ||
Cover protection class | IP42 | ||
Product dimension (W*H*D) | 360×430×191mm | 300×375×145mm | |
Product net weight | 13kg | 10kg | |
Dump load dimension (W*H*D) |
400×390×210mm | ||
Dump load net weight | 12kg | ||
Note: Part of parameters can be adjusted according to customer’s specific demand. |
For more models, please kindly download the related files from the website.
Application
a. Off-grid wind power generation system in Australia b. On-grid wind power generation system in France
c.On-grid wind power generation system in Italy d. Wind power generation project in Hainan
e.Wind power generation project in Huainan f. Wind power generation project in Jiujiang