Applications
Product can be used to supply power for those unmanned regions like independent solar&wind hybrid power generation station, high way, the coastal islands, remote mountainous regions, border posts, landscape lighting site, and street light site. Besides, it can apply to vertical axis wind turbine.
Features
• Recognize 12V/24V automatically
• Wind turbine MPPT track point adjustable
• Complete protection function
• Solar and wind generation capacity and electricity consumption visible.
• Seven modes of load output optional.
• RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee monitor modes optional
Technical Parameters | |
Model | WWS06-24-24 |
Wind Turbine Input | |
Rated input power |
300W(12V Battery) 600W(24V Battery) |
Input voltage range |
0~16Vdc(12V Battery) 0~32Vdc(24V Battery) |
Start charge voltage |
2Vdc(factory default,2Vdc~15Vdc settable) 4Vdc(factory default,4Vdc~30Vdc settable) |
Rated input current | 22Adc |
Manual Brake | Keep press the button for 5s to unload completely, and then recover by manual operation. |
Brake by over current |
26A (factory default,0~26A settable) unload completely .when reached the set current, and recover automatically after working 10mins. |
Brake by overvoltage | Refer to “output overvoltage” control |
Brake by over wind speed (optional) |
18m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after working 10mins. |
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1500r/min settable), unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
PV Input | |
Rated input power | 150W(12V Battery)/300W(24V Battery) |
Max. Open circuit voltage | 24V(12V Battery)/48V(24V Battery) |
Rated input current | 13A |
Reversed connection protection |
YES |
Charge Parameters | |
Rated battery voltage | 12V /24V*recognize automatically |
Temperature compensation function (optional) |
-3mV/℃/2V |
Output Parameters | |
Rated output voltage | 12V/24V *recognize automatically |
Output overvoltage point |
14V (factory default,11Vdc~16Vdc settable) 28V (factory default,22Vdc~32Vdc settable) |
Output overvoltage recovery point |
12.7V (factory default, reduce 1.3V from the output overvoltage point) 25.4V (factory default, reduce 2.6V from the output overvoltage point) |
Max. Output current | 25A |
DC Load Output | |
Output loops | 2 loops |
Output control mode | Both 2 loops could be set in 7 modes, such as light control on&off, light control on and time control off. |
Output voltage range | 10.8V~16V (12V battery);21.6V~32V (24V battery) |
Undervoltage recovery point | Refer to "rated battery voltage" |
Rated output current | 10A/each loop |
Overload protection | 120% rated DC output -1min,150% rated DC output -10s |
Short circuit protection | Instant protection |
General Parameters | |
Rectifier mode | Uncontrolled rectifier |
Display mode | LCD |
Display information |
Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, light control on voltage, light control off voltage, time control duration, load current, wind power generation capacity, solar power generation capacity, load power consumption, and so on. |
Monitoring mode (optional) | RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee |
Monitoring Contents |
Real-time display: Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, wind power generation capacity, solar power generation capacity, Battery status, wind turbine status, day and night, DC overload, DC load short circuit, and so on. |
Parameter setting:Output overvoltage point, wind turbine over current point, wind turbine start voltage, DC load overvoltage/undervoltage/undervoltage recovery point, output mode choice for two loops, light control on voltage, light control off voltage, and wind turbine brake settings. |
|
Lightning protection | YES |
Static loss | <0.6W |
Ambient temperature | -20℃~+40℃ |
Humidity | 0%~90%,No condensing |
Noise | ≤65dB |
Cooling mode | Natural cooling |
Installation mode | Wall-mounted |
Cover protection class | IP52 |
Product dimension (W*H*D) | 150×220×83mm |
Product net weight | 2.3kg |
Note: Part of parameters can be adjusted according to customer’s specific demand. | |
48V | |
Model | WWS06-48-48 |
Wind Turbine Input | |
Rated input power | 600W |
Input voltage range | 0~64Vdc |
Start charge voltage | 8Vdc(factory default,8Vdc~64Vdc settable) |
Rated input current | 11Adc |
Manual Brake | Keep press the button for 5s to unload completely, and then recover by manual operation. |
Brake by over current |
15A (factory default,0~15A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
Brake by overvoltage | Refer to “output overvoltage” control |
Brake by over wind speed (optional) |
18m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after working 10mins. |
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1500r/min settable), unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
PV Input | |
Rated input power | 300W |
Max. Open circuit voltage | 96V |
Rated input current | 7A |
Reversed connection protection |
YES |
Charge Parameters | |
Rated battery voltage | 48V |
Temperature compensation function (optional) |
-3mV/℃/2V |
Output Parameters | |
Rated output voltage | 48V |
Output overvoltage point | 56V (factory default,44Vdc~64Vdc settable) |
Output overvoltage recovery point | 50.8V(factory default, reduce 5.2V from the output overvoltage point) |
Max. Output current | 13A |
DC Load Output | |
Output loops | 2 loops |
Output control mode | Both 2 loops could be set in 7 modes, such as light control on&off, light control on and time control off. |
Output voltage range | 43.2V~64V |
Undervoltage recovery point | Refer to "rated battery voltage" |
Rated output current | 10A/each loop |
Overload protection | 120% rated DC output -1min,150% rated DC output -10s |
Short circuit protection | Instant protection |
General Parameters | |
Rectifier mode | Uncontrolled rectifier |
Display mode | LCD |
Display information |
Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, light control on voltage, light control off voltage, time control duration, load current, wind power generation capacity, solar power generation capacity, load power consumption, and so on. |
Monitoring mode (optional) | RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee |
Monitoring Contents |
Real-time display: Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, wind power generation capacity, solar power generation capacity, Battery status, wind turbine status, day and night, DC overload, DC load short circuit, and so on. |
Parameter setting:Output overvoltage point, wind turbine over current point, wind turbine start voltage, DC load overvoltage/undervoltage/undervoltage recovery point, output mode choice for two loops, light control on voltage, light control off voltage, and wind turbine brake settings. |
|
Lightning protection | YES |
Static loss | <0.6W |
Ambient temperature | -20℃~+40℃ |
Humidity | 5%~95%,No condensing |
Noise | ≤65dB |
Cooling mode | Natural cooling |
Installation mode | Wall-mounted |
Cover protection class | IP52 |
Product dimension (W*H*D) | 150×220×83mm |
Product net weight | 2.3kg |
Note: Part of parameters can be adjusted according to customer’s specific demand. |
Applications
a. Wind&solar hybrid system in Xinjiang b. highway transportation monitoring system in G7
c. Street light project in Heilongjiang d. Road street light project in Hebei
e. Street light project in Xinjiang f. Monitoring project in Inner Mongolia