WWSPCS300 can be used for both on-grid and off-grid systems. Besides, it has adopted advanced LCD touch screen technology, and is easy to operate.
Features
▪ MPPT for wind turbine and solar power generation.▪ Applicable for not only on-grid system, but also off-grid system. And supportable for seamless switch between on-grid and off-grid.
▪ Support grid charging and diesel charging.
▪ Motor soft starting on off-grid state.
▪ Support three-phase 100% unbalanced output load on off-grid state.
Technical Parameters
Model |
WWSPCS300 |
|
Wind Input Data |
||
Rated input power |
10kW |
|
Rated input voltage |
480Vdc |
|
MPPT voltage range |
150-550Vdc |
|
Startup voltage |
150Vdc( factory default, 150Vdc-550Vdc settable) |
|
Over current brake |
24A (factory default, 0-24settable) |
|
PV Input Data |
||
Rated input power |
10kW |
|
Max. PV open circuit voltage |
650Vdc |
|
MPP voltage range at full load |
305V~450Vdc |
|
MPPT efficiency |
>99% |
|
Max. input current |
33Adc |
|
Battery Data |
||
Rated battery voltage |
512 Vdc |
|
Output over-voltage lower limit (start dump load voltage) |
540Vdc |
|
Output over-voltage upper limit (complete dump load voltage |
560Vdc |
|
Max. charging current |
70 Adc |
|
Max. discharging current |
70 Adc |
|
Lithium battery charge& dischargre mode |
According to BMS |
|
Diesel Engine Data |
||
Rated Power |
21kW |
|
Rated voltage |
380/400Vac (Three-phase four-wire) |
|
Rated Frequency |
50Hz |
|
On-Grid Operation Data |
||
Input voltage range |
430~600 Vdc |
|
Rated output power |
30kVA |
|
Rated grid voltage |
380/400Vac (Three-phase four-wire) |
|
Allowed grid voltage range |
310~450Vac |
|
Rated grid frequency |
50Hz |
|
Allowed grid frequency range |
47~53.5Hz |
|
Power factor |
>0.99 |
|
Total Harmonic Distortion (THDi) |
<5% |
|
Off-Grid Operation Data |
||
Input voltage range |
430~600 Vdc |
|
Rated output power |
30kW |
|
Rated output voltage |
400Vac (Three-phase four-wire) |
|
Capacity with unbalanced load |
100% |
|
Total Harmonic Distortion (THDu) |
<3% (linear load) |
|
Rated output frequency |
50Hz |
|
Dynamic voltage transient range |
<10% |
|
Protection |
||
Wind turbine brake protection |
YES |
|
PV reversed connection protection |
YES |
|
Battery reversed connection protection |
YES |
|
Battery over-voltage / under-voltage protection |
YES |
|
IPM module Over-temperature protection |
YES |
|
AC output over-voltage /under-voltage protection |
YES |
|
AC output over-frequency /under-frequency protection |
YES |
|
AC output over-current protection |
YES |
|
AC output short circuit protection |
YES |
|
AC output over load protection |
YES |
|
Surge protection |
YES |
|
Anti-islanding protection |
YES |
|
System Data |
||
Max. Conversion efficiency |
94% |
|
Communication with BMS |
CAN |
|
Display |
LCD touch screen |
|
Display content |
Battery voltage/current/dump energy; PV voltage/ current/ power/accumulative generation energy; wind turbine voltage/current/ power/accumulative generation energy; and grid, diesel or inverter output three phase voltage, current and frequency; Faults protection and so on. |
|
Lightning protection |
YES |
|
Ambient temperature |
-20~+40℃ |
|
Humidity |
5%~95%,(Non-condensing) |
|
Noice |
≤65dB |
|
Cooling method |
Forced air cooling |
|
Ingress protection(IP) rating |
IP21 ( use indoors) |
|
Max. operating altitude |
4000 m (> 1000 m derating) |
|
W*H*D |
The machine |
810mm*1800mm*600mm |
Dump load |
525mm*655mm*430mm |
|
Weight |
The machine |
450kg |
Dump load |
40kg |